66
G8332 Command Reference for ENOS 8.4
Unidirectional Link Detection Information
The
following
commands
display
UDLD
information:
UDLD Port Information
The
following
command
displays
UDLD
information
for
the
selected
port:
show
interface
port
<port
alias
or
number>
udld
Command
mode:
All
UDLD
information
includes
the
following:
Status
(enabled
or
disabled)
Mode
(normal
or
aggressive)
Port
state
(link
up
or
link
down)
Bi
‐
directional
status
(unknown,
unidirectional,
bidirectional,
TX
‐
RX
loop,
neighbor
mismatch)
Table 26.
UDLD
Information
Options
Command Syntax and Usage
show
udld
Displays
all
UDLD
information.
Command
mode:
All
show
interface
port
<port
alias
or
number>
udld
Displays
UDLD
information
about
the
selected
port.
Command
mode:
All
UDLD
information
on
port
1
Port
enable
administrative
configuration
setting:
Enabled
Port
administrative
mode:
normal
Port
enable
operational
state:
link
up
Port
operational
state:
advertisement
Port
bidirectional
status:
bidirectional
Message
interval:
15
Time
out
interval:
5
Neighbor
cache:
1
neighbor
detected
Entry
#1
Expiration
time:
31
seconds
Device
Name:
Device
ID:
00:da:c0:00:04:00
Port
ID:
1
Содержание RackSwitch G8332
Страница 20: ...20 G8332 Command Reference for ENOS 8 4 ...
Страница 32: ...32 G8332 Command Reference for ENOS 8 4 ...
Страница 674: ...674 G8332 Command Reference for ENOS 8 4 ...
Страница 708: ...708 G8332 Command Reference for ENOS 8 4 ...
Страница 732: ...732 G8332 Command Reference for ENOS 8 4 ...
Страница 750: ...750 G8332 Command Reference for ENOS 8 4 ...
Страница 764: ...764 G8332 Command Reference for ENOS 8 4 Russia Electromagnetic Interference EMI Class A statement ...
Страница 765: ... Copyright Lenovo 2016 Appendix C Notices 765 People s Republic of China Class A electronic emission statement ...
Страница 766: ...766 G8332 Command Reference for ENOS 8 4 Taiwan Class A compliance statement ...
Страница 776: ...776 G8332 Command Reference for ENOS 8 4 ...