294
G8332 Command Reference for ENOS 8.4
Match
‐
Inconsistent
Count
of
error
messages
sent
because
the
action
cannot
apply
for
this
match
or
because
there
is
a
set
field
missing
prerequisite.
Available
only
in
OpenFlow
1.3.
Unsupported
‐
Order
Count
of
error
messages
sent
because
the
action
order
in
an
apply
actions
instruction
is
unsupported
for
the
action
list.
Available
only
in
OpenFlow
1.3.
Bad
‐
Set
‐
Type
Count
of
error
messages
sent
due
to
unsupported
type
in
the
set
field
action.
Available
only
in
OpenFlow
1.3.
Bad
‐
Set
‐
Len
Count
of
error
messages
sent
due
to
length
problem
in
the
set
field
action.
Available
only
in
OpenFlow
1.3.
Bad
‐
Set
‐
Argument
Count
of
error
messages
sent
due
to
bad
argument
in
the
set
field
action.
Available
only
in
OpenFlow
1.3.
Bad
Instruction
Available
only
in
OpenFlow
1.3
Unknown
‐
Instructio
n
Count
of
error
messages
sent
due
to
unknown
instruction
in
the
received
flow
mod
message.
Available
only
in
OpenFlow
1.3.
Unsupport
‐
Instruction
Count
of
error
messages
sent
due
to
unsupported
instruction
in
the
received
flow
mod
message.
Available
only
in
OpenFlow
1.3.
Bad
‐
Len
Count
of
error
messages
sent
due
to
wrong
instruction
length.
Available
only
in
OpenFlow
1.3.
Permission
‐
Error
Count
of
error
messages
sent
due
to
permission
error
while
processing
the
instruction.
Available
only
in
OpenFlow
1.3.
Bad
Match
Available
only
in
OpenFlow
1.3
Bad
‐
Type
Count
of
error
messages
sent
due
to
unsupported
match
type
in
the
match.
Available
only
in
OpenFlow
1.3.
Bad
‐
Len
Count
of
error
messages
sent
due
to
wrong
match
length.
Available
only
in
OpenFlow
1.3.
Bad
‐
MAC
‐
Addr
‐
Mask
Count
of
error
messages
sent
due
to
unsupported
MAC
address
mask
in
the
match.
Available
only
in
OpenFlow
1.3.
Bad
‐
IP
‐
Addr
‐
Mask
Count
of
error
messages
sent
due
to
unsupported
IP
address
mask
in
the
match.
Available
only
in
OpenFlow
1.3.
Bad
‐
Wildcards
Count
of
error
messages
sent
due
to
unsupported
combination
of
fields
masked
or
omitted
in
the
match.
Available
only
in
OpenFlow
1.3.
Table 129.
OpenFlow
Statistics
Parameter
Description
Содержание RackSwitch G8332
Страница 20: ...20 G8332 Command Reference for ENOS 8 4 ...
Страница 32: ...32 G8332 Command Reference for ENOS 8 4 ...
Страница 674: ...674 G8332 Command Reference for ENOS 8 4 ...
Страница 708: ...708 G8332 Command Reference for ENOS 8 4 ...
Страница 732: ...732 G8332 Command Reference for ENOS 8 4 ...
Страница 750: ...750 G8332 Command Reference for ENOS 8 4 ...
Страница 764: ...764 G8332 Command Reference for ENOS 8 4 Russia Electromagnetic Interference EMI Class A statement ...
Страница 765: ... Copyright Lenovo 2016 Appendix C Notices 765 People s Republic of China Class A electronic emission statement ...
Страница 766: ...766 G8332 Command Reference for ENOS 8 4 Taiwan Class A compliance statement ...
Страница 776: ...776 G8332 Command Reference for ENOS 8 4 ...