344
G8332 Command Reference for ENOS 8.4
Link Flap Dampening Configuration
The
Link
Flap
Dampening
feature
allows
the
switch
to
automatically
disable
a
port
if
too
many
link
flaps
(link
up/link
down)
are
detected
on
the
port
during
a
specified
time
interval.
The
port
remains
in
the
error
‐
disabled
state
until
it
is
re
‐
enabled
manually
or
re
‐
enabled
automatically
by
the
switch
after
a
timeout
period
has
elapsed.
Table 148.
Link
Flap
Dampening
Configuration
Options
Command Syntax and Usage
[no]
errdisable
link
flap
enable
Enables
or
disables
Link
Flap
Dampening.
Command
mode
:
Global
configuration
errdisable
link
flap
max
flaps
<1
‐
100>
Configures
the
maximum
number
of
link
flaps
allowed
in
the
configured
time
period.
The
default
value
is
5
.
Command
mode
:
Global
configuration
errdisable
link
flap
time
<5
‐
500>
Configures
the
time
period,
in
seconds.
The
default
value
is
30
seconds.
Command
mode
:
Global
configuration
show
errdisable
link
flap
Displays
the
current
Link
Flap
Dampening
parameters.
Command
mode
:
All
Содержание RackSwitch G8332
Страница 20: ...20 G8332 Command Reference for ENOS 8 4 ...
Страница 32: ...32 G8332 Command Reference for ENOS 8 4 ...
Страница 674: ...674 G8332 Command Reference for ENOS 8 4 ...
Страница 708: ...708 G8332 Command Reference for ENOS 8 4 ...
Страница 732: ...732 G8332 Command Reference for ENOS 8 4 ...
Страница 750: ...750 G8332 Command Reference for ENOS 8 4 ...
Страница 764: ...764 G8332 Command Reference for ENOS 8 4 Russia Electromagnetic Interference EMI Class A statement ...
Страница 765: ... Copyright Lenovo 2016 Appendix C Notices 765 People s Republic of China Class A electronic emission statement ...
Страница 766: ...766 G8332 Command Reference for ENOS 8 4 Taiwan Class A compliance statement ...
Страница 776: ...776 G8332 Command Reference for ENOS 8 4 ...