© Copyright Lenovo 2016
Chapter 4: Configuration Commands
479
Virtual Link Aggregation Group (vLAG) Configuration
Virtual
Link
Aggregation
Groups
(vLAGs)
allow
you
to
enhance
redundancy
and
prevent
implicit
loops
without
using
STP.
The
vLAG
acts
as
a
single
virtual
entity
for
the
purpose
of
establishing
a
multi
‐
port
Link
Aggregation
Group
(LAG).
Table 240.
vLAG
Configuration
Options
Command Syntax and Usage
[no]
vlag
adminkey
<1
‐
65535>
enable
Enables
or
disables
vLAG
on
the
selected
LACP
admin
key
.
LACP
LAGs
formed
with
this
admin
key
will
be
included
in
the
vLAG
configuration.
Command
mode:
Global
configuration
vlag
auto
recovery
<240
‐
3600>
Sets
the
duration
in
seconds
of
the
auto
‐
recovery
timer.
This
timer
configures
how
log
after
boot
‐
up
configuration
load,
the
switch
can
assume
the
Primary
role
from
an
unresponsive
ISL
peer
and
bring
up
the
vLAG
ports.
The
default
value
is
300
seconds.
Command
mode:
Global
configuration
no
vlag
auto
recovery
Sets
the
auto
‐
recovery
timer
to
the
default
300
seconds
duration.
Command
mode:
Global
configuration
[no]
vlag
enable
Enables
or
disables
vLAG
globally.
Command
mode:
Global
configuration
[no]
vlag
mac
address
table
refresh
Enables
or
disables
the
periodic
check
of
the
aging
status
of
synchronized
Forwarding
Database
(FDB)
entries.
When
a
MAC
address
is
marked
for
removal
from
the
FDB
table,
the
entry
is
reinstalled
instead.
The
default
setting
is
enabled
.
Note:
This
option
takes
effect
only
if
the
aging
value
for
FDB
entries
is
set
to
40
seconds
or
more.
For
more
details
on
FDB
aging,
see
Command
mode:
Global
configuration
[no]
vlag
peer
gateway
Enables
or
disables
the
forwarding
of
packets
intended
for
the
switch’s
vLAG
peer.
If
a
packet
is
received
by
the
switch,
but
has
the
MAC
address
of
its
vLAG
peer,
it
will
be
locally
forwarded
without
crossing
the
vLAG
inter
‐
switch
link
(ISL),
thus
avoiding
the
loss
of
traffic.
If
the
vLAG
peer
gateway
is
disabled,
packets
addressed
to
the
vLAG
peer
are
sent
across
the
ISL
and
then
dropped
by
the
vLAG
peer.
The
default
settings
is
disabled
.
Note
:
The
vLAG
peer
gateway
must
be
configured
on
both
vLAG
peers.
Command
mode
:
Global
configuration
Содержание RackSwitch G8332
Страница 20: ...20 G8332 Command Reference for ENOS 8 4 ...
Страница 32: ...32 G8332 Command Reference for ENOS 8 4 ...
Страница 674: ...674 G8332 Command Reference for ENOS 8 4 ...
Страница 708: ...708 G8332 Command Reference for ENOS 8 4 ...
Страница 732: ...732 G8332 Command Reference for ENOS 8 4 ...
Страница 750: ...750 G8332 Command Reference for ENOS 8 4 ...
Страница 764: ...764 G8332 Command Reference for ENOS 8 4 Russia Electromagnetic Interference EMI Class A statement ...
Страница 765: ... Copyright Lenovo 2016 Appendix C Notices 765 People s Republic of China Class A electronic emission statement ...
Страница 766: ...766 G8332 Command Reference for ENOS 8 4 Taiwan Class A compliance statement ...
Страница 776: ...776 G8332 Command Reference for ENOS 8 4 ...