5. If the issue is still observed or without power button LED lit on, implement the minimum configuration to
check whether any specific components lock the power permission. Replace the each power supply and
check the power button function after installing the each one.
6. If everything is still done and the issue cannot be resolved, please collect the failure information with
system logs captured to Lenovo support.
Server does not power on
Complete the following steps until the problem is resolved:
1. Check the event log for any events related to the server not powering on.
2. Check for any LEDs that are flashing amber.
3. Check the power LED on the system board.
4. Check if AC power LED is lit on or the amber LED is lit on at the PSU rear side.
5. AC cycle the system.
6. Remove the CMOS battery for at least ten seconds, then, reinstall the CMOS battery.
7. Try to power on the system by IPMI command through XCC or by the power button.
8. Implement the minimum configuration (one processor, one memory module and one PSU without any
adapter and any drive installed).
9. Reseat all power supplies and make sure that AC LEDs on the PSU rear side are lit.
10. Replace the each power supply and check the power button function after installing the each one.
11. If the issue cannot be resolved by above actions, please call service to review the issue symptom and
see whether the system board replacement is necessary.
Memory problems
See this section to resolve issues related to memory.
Common memory problems
•
“Multiple memory modules in a channel identified as failing” on page 149
•
“Displayed system memory is less than installed physical memory” on page 150
•
“Invalid memory population detected” on page 150
Multiple memory modules in a channel identified as failing
Note:
Each time you install or remove a memory module, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
Complete the following procedure to solve the problem.
1. Reseat the memory modules; then, restart the server.
2. Remove the highest-numbered memory module of those that are identified and replace it with an
identical known good memory module; then, restart the server. Repeat as necessary. If the failures
continue after all identified memory modules are replaced, go to step 4.
3. Return the removed memory modules, one at a time, to their original connectors, restarting the server
after each memory module, until a memory module fails. Replace each failing memory module with an
identical known good memory module, restarting the server after each memory module replacement.
Repeat step 3 until you have tested all removed memory modules.
4. Replace the highest-numbered memory module of those identified; then, restart the server. Repeat as
necessary.
149
Содержание 7D7Q
Страница 1: ...ThinkSystem SR250 V2 Maintenance Manual Machine Types 7D7Q and 7D7R ...
Страница 8: ...vi ThinkSystem SR250 V2 Maintenance Manual ...
Страница 20: ...12 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 35: ...2 5 inch drive model Figure 26 Server components 2 5 inch drive model Chapter 2 Server components 27 ...
Страница 42: ...34 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 176: ...168 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 180: ...172 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 183: ......
Страница 184: ......