• If the adapter fails the test, replace the adapter.
Multiple hard drives fail
Complete the following steps until the problem is solved:
• View the Lenovo XClarity Controller event log for events related to power supplies or vibration issues and
resolve those events.
• Make sure that the device drivers and firmware for the hard disk drive and server are at the latest level
Important:
Some cluster solutions require specific code levels or coordinated code updates. If the device is
part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you
update the code.
Multiple hard drives are offline
Complete the following steps until the problem is solved:
• View the Lenovo XClarity Controller event log for events related to power supplies or vibration issues and
resolve those events.
• View the storage subsystem log for events related to the storage subsystem and resolve those events.
A replacement hard disk drive does not rebuild
Complete the following steps until the problem is solved:
1. Make sure that the hard disk drive is recognized by the adapter (the green hard disk drive activity LED is
flashing).
2. Review the SAS/SATA RAID adapter documentation to determine the correct configuration parameters
and settings.
Green hard disk drive activity LED does not represent actual state of associated drive
Complete the following steps until the problem is solved:
1. If the green hard disk drive activity LED does not flash when the drive is in use, run the diagnostics tests
for the hard disk drives. When you start a server and press the key according to the on-screen
instructions, the LXPM is displayed by default. (For more information, see the “Startup” section in the
LXPM documentation compatible with your server at
https://sysmgt.lenovofiles.com/help/topic/lxpm_
frontend/lxpm_product_page.html
.) You can perform hard drive diagnostics from this interface. From the
Diagnostic page, click
Run Diagnostic
➙
HDD test
2. If the drive passes the test, replace the backplane.
3. If the drive fails the test, replace the drive.
Yellow hard disk drive status LED does not represent actual state of associated drive
Complete the following steps until the problem is solved:
1. Turn off the server.
2. Reseat the SAS/SATA adapter.
3. Reseat the backplane signal cable and backplane power cable.
4. Reseat the hard disk drive.
5. Power on the server and observe the activity of the hard disk drive LEDs.
Monitor and video problems
Use this information to solve problems related to a monitor or video.
152
ThinkSystem SR250 V2 Maintenance Manual
Содержание 7D7Q
Страница 1: ...ThinkSystem SR250 V2 Maintenance Manual Machine Types 7D7Q and 7D7R ...
Страница 8: ...vi ThinkSystem SR250 V2 Maintenance Manual ...
Страница 20: ...12 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 35: ...2 5 inch drive model Figure 26 Server components 2 5 inch drive model Chapter 2 Server components 27 ...
Страница 42: ...34 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 176: ...168 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 180: ...172 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 183: ......
Страница 184: ......