Processor replacement
Use the following procedures to remove and install a processor.
Attention:
Before you begin replacing a processor, make sure that you have an alcohol cleaning pad (part
number 00MP352) and gray thermal grease (part number 41Y9292).
Important:
The processor in your server can throttle in response to thermal conditions, temporarily lowering
its speed to reduce heat output. In instances where a few processor cores are throttled for an extremely
short time period (100 ms or less), the only indication might be an entry in the operating system event log
with no corresponding entry in the system XCC event log. If this situation occurs, the event can be ignored
and processor replacement is not required.
Remove the processor
Use this information to remove the processor. This procedure must be executed by a trained technician.
About this task
Attention:
• Read the following section(s) to ensure that you work safely.
–
–
“Installation Guidelines” on page 51
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 11
.
• If the server is installed in a rack, remove the server from the rack.
Watch the procedure
A video of this procedure is available at YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
Procedure
Step 1. Make preparations for this task.
a. Remove the top cover. See
“Remove the top cover” on page 132
b. Remove the air baffle. See
“Remove the air baffle” on page 63
c. Remove the heat sink. See
“Remove the heat sink” on page 86
Step 2. Remove the processor.
114
ThinkSystem SR250 V2 Maintenance Manual
Содержание 7D7Q
Страница 1: ...ThinkSystem SR250 V2 Maintenance Manual Machine Types 7D7Q and 7D7R ...
Страница 8: ...vi ThinkSystem SR250 V2 Maintenance Manual ...
Страница 20: ...12 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 35: ...2 5 inch drive model Figure 26 Server components 2 5 inch drive model Chapter 2 Server components 27 ...
Страница 42: ...34 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 176: ...168 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 180: ...172 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 183: ......
Страница 184: ......