User Manual LW120
Loop(s)
– This parameter define how many times the segment will
loop for the selected link. For example, if you program 2, the
waveform will cycle twice through the same segment before
transitioning to the next link.
Segment #
- This parameter associates waveform segments with
links. You can use different segments for different links or you can
use the same segment for a number of links. There are no
limitations how you associate links to segments, except you can not
program in the sequence table segments that were not defined
earlier.
Adv
–
This field is a special code that is used in conjunction with
the mixed advance mode. This bit flags the LW120 if the selected
link is continuous or stepped. Information on the Mixed sequence
advance mode is given later. “0” flags continuous, “1” flags stepped.
Assuming that you already downloaded waveforms, created and
downloaded sequence table, you can proceed now with the
following description how to set the LW120 to output sequenced
waveforms. Refer to Figure 3-34 for the following.
1. Press the WAVEFORM button
2. Select and press the SEQ option
If you did not make any errors while downloading waveforms and
creating your sequence table, then you should be able to observe
your sequenced waveform at the LW120 outputs.
!
50
TTL
POWER
I
0
OUTPUT
LeCroy
MODEL
100 MS/s ARBITRARY WAVEFORM
!
50
CHAN
1
SYNC
CHAN
2
RESET
CURSOR
MAN
TRIG
TRIGGER
AMPLITUDE
FREQUENCY
UTILITY
WAVEFORM
2
Figure 3-34. Selecting Sequenced Waveforms
STD.
Æ
ARB.
Æ
SEQ.
Æ
Using The Instrument 3-50