User Manual LW120
Parameters
AM
Waveform
Operating Modes
program.
The functional groups in the Main Panel are explained below.
The Parameters group contains two parameters for each channel:
Amplitude and Offset. To access the required parameter, click on the
button below the Channel1 or Channel 2 group until the LED next to
the required parameter turns on. The value that is associated with the
lit LED is displayed on the digital display. You can use the dial,
keyboard, or the [
↑
] [
↓
} keys to adjust the readout to the required
setting. After you modify the reading, press Execute to update the
LW120 with the new reading.
Note
Normal color of the digital reading is dark blue. If you
dout
to dark blue, indicating that the displayed value is the
same as the generator set
modify the reading, the color changes to a lighter shade of
blue, indicating that the LW120 has not been updated yet
with the new parameter. Pressing Execute will update the
instrument and will restore the color of the digital rea
ting.
Also note that the digital readout has an autodetect
mechanism for the high and low limits. You cannot exceed
the limits if you are using the dial but only if you use the
keypad. In case you do, the program will not let you
download an illegal parameter and you’ll be requested to
correct your setting.
The buttons in the AM group let you turn on the AM function. There is
a button for each channel. Click on the Channel 1 button to turn AM
ON for channel 1 and click on the Channel 2 button to turn AM ON for
channel 2. Note that ON is indicated by a red bar at the center of the
button.
The Waveform group is used for selecting between waveform types.
he LW120 provides three types of waveforms: Standard, Arbitrary
and Sequenced. Pressing one of these buttons will cause two
reactions: 1) The LW120 will change the output waveform to the
sele
d
wav
lt
wav
is
pan
in Panel. If you want to change standard
waveform parameters, you can either click on the standard waveform
g Modes group is used for selecting the active trigger
mode for the instrument. You can select between continuous,
triggered, gated and burst modes. There is no additional panel
associated with the continuous mode, but if you press one of the other
T
cted option and 2) Another panel, associated with the selecte
eform type will be invoked and brought to the front. The defau
eform type is Standard. Therefore, the opening screen has th
el behind the Ma
panel, or select this panel from the Panels bar.
The Operatin
ArbExplorer 5-8