Logging Commands
The following CLI commands correspond to the web page entries described above.
To configure logging settings for one or more device ports:
Example:
set deviceport port 2-5,6,12,15-16 baud 2400 locallogging
enable
Note:
Local logging must be enabled for a device port for the
locallog
commands to be
executed. To use the
set locallog clear
command, the user must have permission to clear
port buffers (see
10:
User Authentication
).
set deviceport port <Device Port List or Name> <one or more
deviceport parameters>
Parameters:
emaildelay <Email Delay>
emaillogging <
disable
|bytecnt|charstr>
emailrestart <Restart Delay>
emailsend <
|trap|both>
emailstring <Regex String>
emailsubj <Email Subject>
emailthreshold <Byte Threshold>
emailto <Email Address>
filedir <Logging Directory>
filelogging <enable|
disable
>
filemaxfiles <Max # of Files>
filemaxsize <Max Size of Files>
locallogging <enable|
disable
>
name <Device Port Name>
nfsdir <Logging Directory>
nfslogging <enable|
disable
>
nfsmaxfiles <Max # of Files>
nfsmaxsize <Size in Bytes>
pccardlogging <enable|
disable
>
pccardmaxfiles <Max # of Files>
pccardmaxsize <Size in Bytes>
pccardslot <
upper
|lower>
To view a specific number of bytes of data for a device port:
show locallog <Device Port # or Name> [bytes <Bytes To Display>]
1K is the default.