3: Installation
SecureLinx SLC User Guide
19
Product Information Label
The product information label on the underside of the unit contains the following
information about each specific unit:
Part Number
Serial Number Bar Code
Serial Number and Date Code
Regulatory Certifications and Statements
Technical Specifications
Table 3-1. SLC Technical Specifications
Serial Interface
(Device)
RJ45-type 8-conductor connector (DTE)
Speed software selectable (300 to 115,200 baud)
Serial Interface
(Console)
RJ45-type 8-pin connector (DTE)
Speed software selectable (300 to 115,200 baud)
Network Interface
10Base-T/100Base-TX RJ45 Ethernet
Power Supply
Universal AC power input: 100-240 VAC, 50 or 60 Hz
IEC-type regional cord set included
DC power input :
-24 to -60 VDC
Power Consumption
Less than 20 watts
Dimensions
1U, 1.75 in x 17.25 in x 12 in
Weight
10 lbs or less, depending on the options
Temperature
Operating: 0 to 50 °C (32 to 122 °F), 30 to 90 %RH, non-condensing
Storage: -20 to 70 °C (-4 to 158 °F), 10 to 90 %RH, non-condensing
Relative Humidity
Operating: 10% to 90% non-condensing; 40% to 60% recommended
Storage: 10% to 90% non-condensing
Heat Flow Rate
68 BTU per hour
You can install the SLC either in an EIA-standard 19-inch rack (1U tall) or as desktop
unit. The SLC uses convection cooling to dissipate excess heat.