68
Operating Manual
OMBG3000 – Iss.01
© Copyright 2016
Readable Parameters of the Profibus Module
4.13.3
The data available to the Profibus network is two (16-bit) words, each word
occupying two hex address locations as follows:
Module
Internal Name Parameter
Example
0x0000
Sample Point 1 Last
Reading: Year
e.g. 0x07E0 (2016 dec) is 2016 or
High Byte 7x256 +Low Byte 0x224
0x0002
Sample Point 1 Last
Reading: Month
0x0004
Sample Point 1 Last
Reading: Day
0x0006
Sample Point 1 Last
Reading:
0x0008
Sample Point 1 Last
Reading:
0x000A
Sample Point 1 Last
Reading: Second
0x000C
Sample Point 1 Last
Reading: CH4 x 10
e.g. 0x0259 (601 dec) is 60.1% or
High Byte 2x256 +Low Byte 0x89
0x000E
Sample Point 1 Last
Reading: CO2 x 10
0x0010
Sample Point 1 Last
Reading: O2 x 10
0x0012
Sample Point 1 Last
Reading: Internal Cell
e.g. 0x03E8 (1000 dec) is
1000ppm or High Byte 3x256
+Low Byte 0x232
0x0014
Sample Point 1 Last
Reading:
0x0016
Sample Point 1 Last
Reading: Gas Flow
e.g. 0x0122 (290 dec) is
290ml/min or High Byte 1x256
+Low Byte 0x34
0x0018
Barometric Pressure
e.g. 0x03E1 (993 dec) is 993mbar
or High Byte 3x256 +Low Byte
0x225
0x001A
Sample Point 2 Last
Reading: Year
e.g. 0x07E0 (2016 dec) is 2016 or
High Byte 7x256 +Low Byte 0x224
0x001C
Sample Point 2 Last