Figure 6 - Mains cover removal
4.7
Cable Gland Selection and Cord Anchorage
To maintain the integrity and certification of the equipment a cable gland must
be selected that:
is suitably certified – see section
operating manual for the equipment marking
has a minimum rating of IP65
shall be protected against abrasion and sharp bends at the point where
the cord enters the equipment, by an inlet or bushing with a smoothly
rounded opening
has been fitted and tightened to the recommended torque set by the
manufacturer.
In addition, the cable gland must have a means of anchoring the cable. The
cord anchorage shall relieve the conductors of the cord from strain, including