Lake Shore Model 325 Temperature Controller User’s Manual
Installation
3-1
CHAPTER 3
INSTALLATION
3.0
GENERAL
This chapter provides general installation instructions for the Model 325 Temperature Controller. Please read this entire
chapter before installing the instrument and powering it on to ensure the best possible performance and maintain operator
safety. For instrument operating instructions refer to Chapter 4 and Chapter 5. For computer interface installation and
operation refer to Chapter 6.
3.1
INSPECTION AND UNPACKING
Inspect shipping containers for external damage before opening them. Photograph any container that has significant
damage before opening it. If there is visible damage to the contents of the container contact the shipping company and
Lake Shore immediately, preferably within 5 days of receipt of goods. Keep all damaged shipping materials and contents
until instructed to either return or discard them.
Open the shipping container and keep the container and shipping materials until all contents have been accounted for.
Check off each item on the packing list as it is unpacked. Instruments themselves may be shipped as several parts.
The items included with the Model 325 are listed below. Contact Lake Shore immediately if there is a shortage of parts
or accessories. Lake Shore is not responsible for any missing items if not notified within 60 days of shipment.
Inspect all items for both visible and hidden damage that occurred during shipment. If damage is found, contact
Lake Shore immediately for instructions on how to file a proper insurance claim. Lake Shore products are insured
against damage during shipment but a timely claim must be filed before Lake Shore will take further action. Procedures
vary slightly with shipping companies. Keep all shipping materials and damaged contents until instructed to either return
or discard them.
If the instrument must be returned for recalibration, replacement or repair, a Return Authorization (RA) number must be
obtained from a factory representative before it is returned. The Lake Shore RA procedure is given in Section 8.2.
Items Included with Model 325 Temperature Controller:
1
Model 325 Instrument
1
Model 325 User’s Manual
2
Sensor input mating connector, 6-pin DIN
1
Heater output connector, dual banana, for Loop 1 Heater Out
1
Terminal block mating connector, 2-pin terminal block, for Loop 2 Heater Out
1
Line Power Cord
1
Line Power Cord for Alternative Voltage*
*
Included only when purchased with VAC-120-ALL power option.
Содержание 325
Страница 4: ...Lake Shore Model 325 Temperature Controller User s Manual...
Страница 6: ......
Страница 22: ...Lake Shore Model 325 Temperature Controller User s Manual 1 10 Introduction This Page Intentionally Left Blank...
Страница 47: ...Lake Shore Model 325 Temperature Controller User s Manual 3 11 This Page Intentionally Left Blank...
Страница 48: ...Lake Shore Model 325 Temperature Controller User s Manual 3 12 This Page Intentionally Left Blank...
Страница 76: ...Lake Shore Model 325 Temperature Controller User s Manual 4 28 Operation This Page Intentionally Left Blank...
Страница 122: ...Lake Shore Model 325 Temperature Controller User s Manual 6 36 Remote Operation This Page Intentionally Left Blank...
Страница 128: ...Lake Shore Model 325 Temperature Controller User s Manual 7 6 Options and Accessories...