Up/Down Cylinder Lowering (Operation) "With Slight Lift Inactivated"
0.8
1.6
0.8
2.0
2.0
B1 A2
A1
A3
B2
B3
R5 : 17.2MPa
P
T
P
T
R5
E
A1
B1
B2
P1
P2
Electromagnetic
check valve
Electromagnetic
check valve
Up/down cylinder
Mower #2
Mower #3
Mower #5
Mower #1
Mower #4
Slow return valve
Slow return valve
Mower ♯1
Mower ♯5
Mower ♯3
Mower ♯4
Mower ♯2
Gear motor
Gear motor
Gear motor
Gear motor
Gear motor
Double Gear pump
Double multi-valve
Oil cooler
Stop valve
Suction filter
150W
High pressure
Low pressure/charge
Intake - return
Direction
9rksye-003E
Up/Down Cylinder Lowering (Operation) "With Slight Lift Inactivated"_001
LM531
Hydraulic System
Page 4-24