Engine Start/Stop Circuit
There are four switches related to engine operation, each of which operates a relay in coordination
with each switch.
These are configured so that the following switches control multiple circuits.
Reel rotation switch
Seat switch
Proximity switch/Parking brake
Proximity Switch/Pump neutral
Operating outline of electrical circuits during engine operation
When engine operation conditions are satisfied, the relay/engine stop solenoid operates and the
fuel cut solenoid is activated along with it.
While the fuel cut solenoid is activated, fuel continues to be supplied to the engine to continue
operation of the engine.
If there is a malfunction such as the starter operating but the engine does not start, or the engine
starts but then stops, inspect and adjust the engine start/stop circuit
1.
2.
3.
4.
・
Electrical System
LM531
Electrical System
Page 5-19
Electrical Circuit Configuration
Содержание Baroness LM531
Страница 4: ...LM531 Introduction...
Страница 6: ...LM531 Contents...
Страница 12: ...LM531 Safety Page 1 6 Safety Signs and Instruction Signs...
Страница 40: ...LM531 Maintenance Standards and Maintenance Page 3 26 Lubrication...
Страница 55: ...Hydraulic System LM531 Hydraulic System Page 4 15 Hydraulic Circuit Configuration...
Страница 84: ...LM531 Hydraulic System Page 4 44 Measurement...
Страница 91: ...Electrical System LM531 Electrical System Page 5 7 General Inspection and Repair...
Страница 132: ...LM531 Electrical System Page 5 48 Electrical components...
Страница 152: ...LM531 Troubleshooting Page 7 8 Relating to Mower Unit...
Страница 153: ...Specifications Page 8 2 Maintenance Schedule Page 8 3 List of Consumables Page 8 8 Reference LM531 Reference Page 8 1...