Calibrating the Feelers
3-9
KVAL Operation/Service Manual
Identify the Hinge and Lock Head Designations
If the Hinge Pockets and Lock Pockets are out of the expected results, select the desired
Head Cal-
ibrations
from the list to adjust. The figure below identifies the carriage heads to match to the cal-
ibration list.
Hinge Head
FIGURE 3-11.
Carriage Designators
Using the Carriage Axes Calibrations
The
Carriage Axes
calibration treats the
entire tool set within the carriage as one unit
. There-
fore, if all parameters or a particular cut are out of specifications, use this calibration adjustment.
1.
Identify the cut out of spec-
ification.
2.
Select
Carriage A
3.
Measure the cut and follow
the instructions in
“How to
Enter Calibration Data” on
page 3-6
.
Содержание Edge-SS
Страница 5: ...KVAL Edge SS Operation Service Manual ...
Страница 12: ...KVAL Edge SS Line Operation Service Manual ...
Страница 30: ...How to Download the Service Application 1 18 KVAL Operation Service Manual Page Intentionally Left Blank ...
Страница 32: ...Safety Sign Off Sheet 1 20 KVAL Operation Service Manual ...
Страница 35: ...Definitions 2 45 KVAL Operation Service Manual ...
Страница 91: ...Definitions KVAL Operation Service Manual 2 56 ...
Страница 109: ...System IT Administration 4 4 KVAL Operation Service Manual ...
Страница 142: ...Collet Torque Values 5 33 KVAL Operation Service Manual ...
Страница 143: ...Troubleshooting Electrical Problems 6 30 KVAL Operation Service Manual ...
Страница 173: ......
Страница 177: ......
Страница 178: ......
Страница 179: ......