About Switches and Sensors
6-22
KVAL Operation/Service Manual
.
The L
imit Switch
is activated by an assembly moving a switch arm.
• .Depending on the model of limit switch, the
amount of “pre-travel” (amount of movement from
the arms resting position) is either 5 or 20 degrees
before the limit switch actuates (Clicks).
Switch Arm
Using Sensors to Trouble Shoot
• Photo Sensors often get dirty. Make sure they are clean. If they are not clean, debris
may block the signal or provide a false signal.
• Check output voltages of the sensors in the
active
mode. The voltage should effec-
tively equal
0 VDC
• Check the output voltages of the sensors in
inactive
mode.The voltage should effec-
tively equal
24 VDC
The distance from an eye to the door should be in range. Typically the range should be
3/4'' to 7/8'' from the top of all eyes to the door.
Содержание Edge-SS
Страница 5: ...KVAL Edge SS Operation Service Manual ...
Страница 12: ...KVAL Edge SS Line Operation Service Manual ...
Страница 30: ...How to Download the Service Application 1 18 KVAL Operation Service Manual Page Intentionally Left Blank ...
Страница 32: ...Safety Sign Off Sheet 1 20 KVAL Operation Service Manual ...
Страница 35: ...Definitions 2 45 KVAL Operation Service Manual ...
Страница 91: ...Definitions KVAL Operation Service Manual 2 56 ...
Страница 109: ...System IT Administration 4 4 KVAL Operation Service Manual ...
Страница 142: ...Collet Torque Values 5 33 KVAL Operation Service Manual ...
Страница 143: ...Troubleshooting Electrical Problems 6 30 KVAL Operation Service Manual ...
Страница 173: ......
Страница 177: ......
Страница 178: ......
Страница 179: ......