Initial Powering Operations for the 990-FX Line
KVAL Operation/Service Manual
2-34
Home the 990-FX
The 990-FX must go through a homing routine before any operations are performed. The homing
routine sets a zero reference from which the 990-FX measures its movement and cutting process.
If power is lost or the 990-FX is re-set, the homing routine must be performed again to reset the
zero reference
Press the
Home
button on the
Main Screen
touch screen.
6.
Initiate the
Hinge Loaded
to act as a Reset.
Note:
This process is a safety precaution to ensure the no personnel is in the machine
staging area.
Push the
Hinge
Loaded Button
7.
All lights on the status light panels on the electrical
box should be illuminated.
Note:
If a status light does not turn on during the power
up process, see
the trouble shooting chapter in the
Service Manual.
1.
The machine will move to the home position at the
in-feed end of the machine.
2.
The machine will then move to about the middle of
its travel.
The 990-FX is now ready for work.
Содержание 990FX
Страница 4: ...KVAL 990 FX Operation Service Manual ...
Страница 30: ...Safety Sign Off Sheet KVAL 990 FX Operation Service Manual 1 20 ...
Страница 85: ...Glossary of Common Terms 2 55 KVAL Operation Service Manual ...
Страница 90: ...System IT Administration 3 5 KVAL Operation Service Manual ...
Страница 129: ...Collet Torque Values 4 39 KVAL 990 FX Operation Service Manual ...
Страница 130: ...Collet Torque Values KVAL 990 FX Operation Service Manual 4 40 ...
Страница 164: ...Network System Overview KVAL Operation Service Manual 5 34 ...
Страница 168: ...KVAL 990 FX Operation Service Manual ...
Страница 169: ......
Страница 170: ......
Страница 171: ......