Troubleshooting Basics
5-5
KVAL Operation/Service Manual
Before you Adjust
Analyze the Sub Systems
1.
Check the
Load
for mechanical issues
• Is the Load “bound up?
• Is there sufficient lubrication?
• Is it an alignment issue?
• Is anything damaged?
2.
Check the
Position Feed Back
.
Determine What:
What Subsystem is Respon-
sible for the Failed Sequence
Step.
Analyze
the subsystem:
Check the
Load
.
Check the
Position Feed Back
.
Check the
Positioning System
See
TABLE 5-1.
Typical KVAL Machine Sequence
Typical Machine Sequence
Responsible Subsystem
1. Move Door into Position
Feed System
2. Clamp the Door
Door Clamp
3. Make the Cuts
Cutter Positioning
Cutter Power
4. Unclamp the Door
Door Clamp
5. Move Door Out
Feed System
6. Wait for Next Door
Feed System
Basic Troubleshooting Steps
Determine Where:
The Sequence Step
Where
the Failure Occurs
What was the Machine Trying to Do?
What Was the Machine Trying to Do Next?
Check the Sequences in the Table Below.
How is the Broken Section Suppose to Work?
What is Keeping the Broken Section From
Working?
What Part of the Machine is not Working?
Check the Subsystems in the Table Below.
Ask
Narrow
Verify
Содержание 990FX
Страница 4: ...KVAL 990 FX Operation Service Manual ...
Страница 30: ...Safety Sign Off Sheet KVAL 990 FX Operation Service Manual 1 20 ...
Страница 85: ...Glossary of Common Terms 2 55 KVAL Operation Service Manual ...
Страница 90: ...System IT Administration 3 5 KVAL Operation Service Manual ...
Страница 129: ...Collet Torque Values 4 39 KVAL 990 FX Operation Service Manual ...
Страница 130: ...Collet Torque Values KVAL 990 FX Operation Service Manual 4 40 ...
Страница 164: ...Network System Overview KVAL Operation Service Manual 5 34 ...
Страница 168: ...KVAL 990 FX Operation Service Manual ...
Страница 169: ......
Страница 170: ......
Страница 171: ......