![Kval 990FX Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/kval/990fx/990fx_operation-and-service-manual_2012811036.webp)
Summary of the Controls on the Machine Line
KVAL Operation/Service Manual
2-6
Foot Pedal and Control Box
The control box is located near the center six shooter on the front section of the machine. Includes
manual controls of the Jamb Clamp, RH or LH orientation, and six shooter operation.
Door Clamp Pedal:
The door clamp pedal activates the door clamp to
either clamp or unclamp the door. Can be used in manual mode to posi-
tion a door. Press once to clamp, press again to unclamp
.
Jamb Clamp Pedal:
The jamb clamp pedal activates the jamb clamps
to clamp the jamb in place. or to unclamp a jamb. Press once to clamp,
press again to unclamp
.
See “Machine Start Summary” on page 2-30.
Door Clamp / Un-Clamp
Jamb Clamp / Un-Clamp
Foot Pedal
Control Box
Start Sequence:
Press to start the door sequence that was pre-selected by
the operator via the touch-screens. Push when jamb is loaded and
clamped properly, hinges have been loaded, and hands are safely out of
the way.
Note:
Be prepared for the front section routers to move into position and
begin routing, as well as the back section routers, lock bore, and bolt drill.
The Six-Shooter heads will also begin to move into position
.
Door Auto RH / LH:
Press for Auto Run, or to receive either a left-hand or
right-hand incoming door. When in “Auto Door” mode, the 990-FX receives
information about the incoming door from the incoming machine.
Unclamp:
Use this button when performing a manual door run to unclamp
the door after machining is complete. If you are performing an auto run and
have activated the “Auto Unclamp” button on the auto run touchscreen,
then pressing the 990-FX control box “Unclamp” button is unnecessary.
Emergency Stop:
The red emergency stop button halts machine operation;
it does not kill electrical power in the machine.
Important: I
f, at any time, the operator must work on or enter the machine
for any reason, shut off electrical power and properly lock- and tag-out the
machine to remove electrical energy from the machine. If a problem occurs
during operation, push the emergency stop button.
Содержание 990FX
Страница 4: ...KVAL 990 FX Operation Service Manual ...
Страница 30: ...Safety Sign Off Sheet KVAL 990 FX Operation Service Manual 1 20 ...
Страница 85: ...Glossary of Common Terms 2 55 KVAL Operation Service Manual ...
Страница 90: ...System IT Administration 3 5 KVAL Operation Service Manual ...
Страница 129: ...Collet Torque Values 4 39 KVAL 990 FX Operation Service Manual ...
Страница 130: ...Collet Torque Values KVAL 990 FX Operation Service Manual 4 40 ...
Страница 164: ...Network System Overview KVAL Operation Service Manual 5 34 ...
Страница 168: ...KVAL 990 FX Operation Service Manual ...
Страница 169: ......
Страница 170: ......
Страница 171: ......