11. - Maintenance and storage
Venta 3030-3530-4030
111
RN034AGB D
Seed Drill
11.4.2 Check metering unit seal lips
Check lip condition daily for damage or cracks.
The lower lip seals must be positioned with little
pressure at the highest point of the metering cells.
If necessary:
- Open locks (1).
- Open the closing flap (2).
-
Check condition of the sealing lips on the
metering unit (3).
- Immediately replace faulty parts.
1
2
3
1