29
ASSEMBLY INSTRUCTIONS
5. Tighten up the lock nuts at both sides of the valve stay
to secure the cables in place.
A
When assembling the switch section, keeping the self-
level on/off lever downward.
A
With the lock nuts tight in position, move the lever to
make sure that the cables and spools behave
smoothly as specified.
6. Check the position of the valve spool for self-leveling
relative to the lever position. If it is not following the
figures below, reconfigure the cable assembling
process.
[Lower position (self-leveling is on)]
[Upper position (self-leveling is off)]
C
Control valve cover section
1. Attach the valve cover to the valve stay.
A
In case the hydraulic hose contacts the valve cover,
readjust the angle of hose.
(1) 6-M16 lock nuts
Tightening Torque
60.0 to 80.0 N-m
(6.1 to 8.2 kgf-m)
(44.3 to 59.0 ft-lbs)
(1) Self-level on/off lever
(Lower position)
(2) Self-level on/off lever
(Upper position)
(3) Spool for self-leveling
(A) Spool length is same
(B) Spool length is shorter
than others
(1) Valve cover
(2) 3-M8 x 20 bolts with washers