ASSEMBLY INSTRUCTIONS
46
C
Hydraulic hoses section
1. Remove the bolts which the connector assembly stay
is fasten, then fasten the accumulator assembly (RH)
to the main frame with the stay.
A
Kits has 90 mm and 110 mm bolts, use applicable
bolts due to 3rd function valve kit is installed or not.
2. Connect the hoses as shown below.
[For Standard valve]
[For Self-level valve (if equipped)]
(1) Main frame (RH)
(2) Accumulator assembly (RH)
(3) 2-M10 x 90 bolts (without 3rd function valve kit)
2-M10 x 110 bolts (if equipped with 3rd function valve kit)
(4) 2-M10 plain washers (original)
(5) Connector assy stay (original)
(6) 2-M10 spring lock washers (original)
(7) 2-M10 nuts (original)
(1) Hydraulic hose
(850 mm (33.5 in.), 3/4-UNF and 3/4-UNF)
(2) Hydraulic hose
(385 mm (15.2 in.), 3/4-UNF and 3/4-UNF)
(1) Hydraulic hose
(850 mm (33.5 in.), 3/4-UNF and 3/4-UNF)
(2) Hydraulic hose
(385 mm (15.2 in.), 3/4-UNF and 3/4-UNF)