Preparing the Big Pack Baler
BP380-7-034
3
2
a
b
1
1
3.4.7 Fire Extinguisher
There is a fire extinguisher (1) mounted on the left hand
side of the machine beside the bale channel.
Please have the fire extinguisher
registered. This is the only way of
guaranteeing that the necessary
inspections are carried out.
3.4.8 Shunting Without an Air Brake Connected
If the hoses for the air brake are not connected to a
brake system, the big pack baler cannot be operated.
If a minimum pressure of 4 bar is present in the reser-
voir tank (2) for the big pack baler's brake system, the
brakes can be freed by pressing the push button (1) to
position (a). As soon as the hoses are connected up to
an air brake system again the push button returns to its
original position (b).
If the air pressure in the reservoir tank (2) falls below
4 bar, the remaining pressure must be released at the
water evacuation valve (3). Only then can the big pack
baler be operated again.
Before operating the valve or before
depressurizing the reservoir tank, secure
the machine to prevent it moving on its
own.