43. Air piping
• Use a urethane or nylon tube of a φ8 outer dimension for the air piping.
• Use clean air through a dryer or filter for the air supply.
• Connecting the nozzle
Select a nozzle to attach to the blow unit according to the workpiece to remove static charge/particles.
Nozzle piping bore: Rc1/8
Do not use nozzles other than the following nozzles. Do not close the ionized air outlet with a plug, etc.
Recommended tightening torque:5 N
・
m
(For pinpoint removal of static charge/particles)
Nozzle: DTY-NZW-PP02 nozzle bore φ2.0 mm (It is dedicated particles removal nozzle)
DTY-NZW-PP03 nozzle bore φ3.0 mm
DTY-NZW-PP04 nozzle bore φ4.0 mm
(For removal of static charge/particles in a large area)
Nozzle: DTY-NZW-SW60 nozzle shower 60°
DTY-NZW-SW90 nozzle shower 90°
DTY-NZW-FT01 nozzle flat
To adjust the nozzle angle, use in conjunction with the nozzle joint: DTY-NZW- NJ01.
After adjusting the nozzle angle, lock it and use it.
Angle adjustable range of the nozzle joint: ±25°
Recommended tightening torque: Body 1 N
・
m / Nozzle 0.3 N
・
m
44. Exhaust Ventilation
• Dust collecting unit (DTY-ZMW01-□-□) has a dust collection filter in it.
There is a fan inside the unit. Be careful about an injury due to the fan and the fan damage.
The filter on the fan filter (OUT) side collects particles.
(The filter on the fan filter (IN) side is a filter to prevent larger particles from entering inside the dust collecting unit.)
The filters are consumables. Replace the filter (DTY-ZFF-WB/ DTY-ZFR-WB) when the filter is clogged or contaminated.
• The exhaust duct outer diameter is φ76.3 if the dust collecting unit is not used but the duct attaching bracket (DTY-ZBRB-WB)
(additional part) is used,
When connecting exhaust hose, pay attention to the exhaust resistance. (Recommended exhaust hose nominal diameter: φ75)
Air piping joint
Air IN port
Fan filter (OUT)
Fan filter (IN)
Inhalation irection
Exhaust direction
Filter
IN side: DTY-ZFF-WB
OUT side: DTY-ZFR-WB
Nozzle (blow air outlet)
[Front]
[Side]
Nozzle (ionized air outlet)
Nozzle joint: DTY-NZW-NJ01
Note:Prepare sufficientain supply to minimize the pressure drop during operation
Содержание ION WIPER DTY-WB01
Страница 1: ...X904484 ION WIPER Separate Type DTY WB01 DTY WBM01 S DTY WBM01 L Operating Instructions Ver 1 0 ...
Страница 23: ... 47 Box type A4 size DTY WBM01 S Aperture Aperture Depth ...
Страница 24: ... 48 Box type A3 size DTY WBM01 L Aperture Aperture Depth ...
Страница 25: ... 49 Memo ...
Страница 27: ...2018 年 12 月 Ver 1 0 KG KOGA NEI CORP PRINTED IN JA PA ...