- 39 -
6-3-2. Read Input Status (function code: 2)
Read by the function code 2.
(Readable binary data, such as ON/OFF, is deployed)
Data address
Term
Description
0
ALARM
This indicates the same state as the I/O connector terminal No.1: ALARM.
0: OFF, 1: ON
1
CHECK
This indicates the same state as the I/O connector terminal No.2: CHECK.
0: OFF, 1: ON
2
MAINT
This indicates the same state as the I/O connector terminal No.3: MAINT.
0: OFF, 1: ON
3
EPS
This indicates the same state as the I/O connector terminal No.4: EPS.
0: OFF, 1: ON
4
DUST
This indicates the same state as the I/O connector terminal No.5: DUST.
0: OFF, 1: ON
5
END
This indicates the same state as the I/O connector terminal No.6: END.
0: OFF, 1: ON
6
VAC_START
This indicates the same state as the I/O connector terminal No.7:
VAC_START.
0: OFF, 1: ON
7
STOP
This indicates the same state as the I/O connector terminal No.8: STOP.
0: OFF, 1: ON
8
START
This indicates the same state as the I/O connector terminal No.9: START.
0:OFF, 1:ON
9
ZC
(Zero calibration)
This indicates the same state as the I/O connector terminal No.10: ZC.
0:OFF, 1:ON
10
Touch Sensor
This indicates the detection state of the photoelectronic sensor.
0:OFF, 1:ON
11
EPS Connect
Connection state of the electrostatic potential sensor.
0: not connected, 1: connected
12
DUST1 Connect
Connection state of the dust collecting unit 1
0: not connected, 1: connected
* Dust collecting unit connected to the dust collecting unit 1 connector
CON3
13
DUST2 Connect
Connection state of the dust collecting unit 2
0: not connected, 1: connected
* Dust collecting unit connected to the dust collecting unit 2 connector
CON4
14
DUST1 FAN Error
Fun error state of the dust collecting unit 1
0: normal, 1: error
15
DUST2 FAN Error
Fun error state of the dust collecting unit 2
0: normal, 1: error
16
ELK CHECK
CHECK state of the ionizer (DTY-ELK01)
0: OFF, 1: ON
17
ELK ALARM
ALARM state of the ionizer (DTY-ELK01)
0: OFF, 1: ON
18
ELK HV
Discharge state of the ionizer (DTY-ELK01)
0: OFF, 1: ON
19
ELK Maint
Maintenance signal of the ionizer (DTY-ELK01)
0: OFF, 1: ON
20
Blow Valve Maint
Maintenance signal for blow valve
0: OFF, 1: ON
24
Current Over ALARM
Overcurrent error state of the I/O connector terminal No.1: ALARM
0: normal, 1: overcurrent error
25
Current Over CHECK
Overcurrent error state of the I/O connector terminal No.2: CHECK
0: normal, 1: overcurrent error
26
Current Over MAINT
Overcurrent error state of the I/O connector terminal No.3: MAINT
0: normal, 1: overcurrent error
27
Current Over EPS
Overcurrent error state of the I/O connector terminal No.4: EPS
0: normal, 1: overcurrent error
28
Current Over DUST
Overcurrent error state of the I/O connector terminal No.5: DUST
0: normal, 1: overcurrent error
29
Current Over END
Overcurrent error state of the I/O connector terminal No.6: END
0: normal, 1: overcurrent error
30
Current Over START
Overcurrent error state of the I/O connector terminal No.7: START
0: normal, 1: overcurrent error
Содержание ION WIPER DTY-WB01
Страница 1: ...X904484 ION WIPER Separate Type DTY WB01 DTY WBM01 S DTY WBM01 L Operating Instructions Ver 1 0 ...