- 35 -
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T1
T3
T5
T4
T7
T1
T8
T2
T6
[Time chart]
• When the blow time is specified (blow time setting switch No.0 - A)
Photoelectronic sensor or
external input [START]
External output
[VAC_S]
External output [END]
External input [STOP]
Dust collecting unit
(DC fan)
Ionized air
Air blow
Symbol
Term
Time [ms]
Remark
T1
Input signal ON delay time
100
Operation starts when the photoelectronic sensor or external input
[START] is greater than T1
T2
Dust collecting operation time prior to blow
200
Dust collecting operation time prior to air blow
T3
Ionized air time prior to blow
100
Ionized air time prior to air blow
T4
Air blow time
Set by the blow time
setting switch
Air blow time
T5
Ionized air time after blow
0
Ionized air blow time after air blow
T6
Dust collecting operation time after blow
200
Dust collecting operation time after air blow
T7
External output [END] time
200
External output time (1 shot pulse)
T8
Input signal OFF delay time
100
The subsequent operation is accepted when the photoelectronic
sensor or external input [START] is greater than T8
• Continuous blow is specified (Setting switch No. B - F)
Photoelectronic sensor or
external input [START]
External output
[VAC_S]
External output [END]
External input [STOP]
Dust collecting unit
(DC fan)
Ionized air
Air blow
Symbol
Ter m
Time [ms]
Remar k
T1
Input signal ON delay time
100
Operation starts w hen the photoelectronic sensor or external input
[START] is greater than T1
T2
Dust collecting operation time pr ior to blow
200
Dust collecting operation time pr ior to air blow
T3
Ionized air time prior to blow
100
Ionized air time prior to air blow
T4
Air blow time
Photoelectronic sensor or external input [START]
When ON (excluding T2/T3, including T8)
Air blow time
T5
Ionized air time after blow
0
Ionized air blow time after air blow
T6
Dust collecting operation time after blow
200
Dust collecting operation time after air blow
T7
External output [END] time
200
External output time (1 shot pulse)
T8
Input signal OFF delay time
Set by the blow time setting sw itch
Air blow operation stops w hen the setting is greater than T8 (OFF)
The operation continues w hen the photoelectronic sensor or the
external input [START] is OFF once and back to ON again w ithin T8.
Note: When the external input [STOP] is set to ON, the photoelectronic sensor/external input [START] is not accepted.
To enable the operation again, set the external input [STOP] and the photoelectronic sensor/external input [START] to OFF, and
then activate the operation.
Set by the blow intermittent frequency switch No.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T4
T3
T5
T1
T1
T2
T6
T7
T8
Set by the blow intermittent frequency switch No.
Содержание ION WIPER DTY-WB01
Страница 1: ...X904484 ION WIPER Separate Type DTY WB01 DTY WBM01 S DTY WBM01 L Operating Instructions Ver 1 0 ...
Страница 23: ... 47 Box type A4 size DTY WBM01 S Aperture Aperture Depth ...
Страница 24: ... 48 Box type A3 size DTY WBM01 L Aperture Aperture Depth ...
Страница 25: ... 49 Memo ...
Страница 27: ...2018 年 12 月 Ver 1 0 KG KOGA NEI CORP PRINTED IN JA PA ...