- 29 -
4. Installation and Wiring/Piping
41. Installation Precaution
• This product should be used an indoor environment. When installing this product, pay attention to the pollution by water and oil,
high temperature, and high humidity.
• Especially, avoid a place where dew condensation is anticipated.
• Use the L-shaped bracket to securely fix the product. Do not install this product to an unstable place.
The fixing screws for the L-shaped bracket are M4 x length 5 mm. When the screws are prepared at the customer site, use
screws of M4 x length 5 mm to 10 mm.
• Box type DTY-WBM01 should be installed on a robust and flat place like a workbench. Do not install this product to an unstable
place.
• For the blow unit side operation area/air piping (φ8 tube), keep a space larger than 100 mm when installing this product.
Also, for the exhaust from the dust collecting unit, keep a space larger than 100 mm when installing this product.
42. Wiring
4-2-1. Power and ground connection
Connect the power cable (DTY-ZDW-□) or the AC adapter (DTY-ZPS4) to the power connector POWER.
Connect the cable securely by inserting the cable until the lock lever locks on the power connector. To disconnect the cable push
down the lock lever fully and hold the connector and remove the cable. Do not apply excessive force to the lead wire.
Connect to the power (DC 24 V). The ground wire (green) of the power cable must be grounded.
(Connection using the power cable: DTY-ZDW-□)
Terminal No.
Symbol
Connecting cable color
1
NA
White
2
0 V
Black
3
24 VDC
Red
4
FG
Green
Connect the red power cable (terminal No.3) to the 24 V
DC power.
Connect the black power cable (terminal No.2) to the 0 V power.
Ground the green power cable (terminal No.4).
Note: Connect the red and black power cables correctly.
As the reverse connection protective circuit is built-in, the product would not be damaged but does not operate correctly.
(Connection using the adapter: DTY-ZPS4)
Connect the AC adapter cable to the AC adapter, and connect to the AC outlet (100 VAC - 240 VAC, 50 Hz/60 Hz).
Ensure to ground the ground wire (green).
Note: Always ground the ground wire (green) to prevent static charge and to achieve full performance of the ionizer.
Incomplete grounding would degrade the discharge performance.
Note: 0 V and FG (ground terminal) are internally connected.
Power connector
Power cable: DTY-ZDW-□
AC adapter: DTY-ZPS4
AC adapter cable
Ground wire
To the AC outlet
Содержание ION WIPER DTY-WB01
Страница 1: ...X904484 ION WIPER Separate Type DTY WB01 DTY WBM01 S DTY WBM01 L Operating Instructions Ver 1 0 ...
Страница 23: ... 47 Box type A4 size DTY WBM01 S Aperture Aperture Depth ...
Страница 24: ... 48 Box type A3 size DTY WBM01 L Aperture Aperture Depth ...
Страница 25: ... 49 Memo ...
Страница 27: ...2018 年 12 月 Ver 1 0 KG KOGA NEI CORP PRINTED IN JA PA ...