8. Troubleshooting
81. When a Problem Occurs
When contacting us for a problem, please inform us about the following items as specific as possible:
Item
Description (example)
What
Model (blow unit: DTY-WB01/Box type DTY-WBM01-S/-L)
Others
When
Purchase date (serial No.)
Period of service, operating condition
When the power is on; One hour after the power is on
In what situation
During operation
During configuration
What happened
The unit does not function
An error occurs
Frequency
Always occurs
Once in an hour
The problem is not reproduced
82. When Alarms Are Issued and Their Resolution
When the I/O connector ALARM signal output is ON, it is considered that an alarm is issued.
Also, the blow unit ALM (red) LED turns on/flashes. (For the details, refer to "5-2. LED Indicators".)
When an alarm is issued, refer to the solutions in "8-3. Alarm List".
83. Alarm List
Alarm
Code
Alarm Subject
Descript ion
B ehavior
Possible Cause
Resolution
1001
I/O connect or terminal No.1 ALARM overcurrent
Stop
1002
I/O connect or terminal No.2 CHECK overcurrent
Stop
1003
I/O connect or terminal No.3 MAINT overcurrent
Stop
1004
I/O connect or terminal No.4 EPS overcurrent
Stop
1005
I/O connect or terminal No.5 DUST overcurrent
Stop
1006
I/O connect or terminal No.6 END overcurrent
Stop
1007
I/O connect or terminal No.7 VAC STA RT
overcurrent
Stop
1020
Memory failure
Stop
1030
Communication error (CRC mismatch occurred)
Continue
1031
Communication error (exception response
occurred)
Continue
2010
Dust collecting unit 1
2020
Dust collecting unit 2
3010
Zero calibration error
Continue
・
Zero calibrat ion was performed within the range (within
±200 V)
(±2000 V in the high voltage mode)
P erform calibration within the range (within ±200 V)
(± 2000 V in the high voltage mode)
3020
E lectrostatic potential sensor
Stop
The sensor is broken
Remove the sensor from the unit and attach it again.
If t he problem persist s, contact us.
4010
Feature failure
Stop
The piezoelectric transformer is broken.
4020
Discharge failure
Continue
A bnormal discharge occurred
Electrostatic
potential sensor
Ionizer
S hut the power, and check for any issues on the
discharge needle, such as contamination with dust.
If t he problem persist s, contact us.
Blow unit
・
The load connected to the I/O out put got short
circuited.
・
DC 24 V is applied without the load.
S hut the power, and check the load.
A fter removing the cause of t he alarm, turn on the device.
・
Error in the communication settings
・
The power was turned ON while communicat ing with
support soft ware
・
Effect by the noise
Check the communication settings.
Connect before applying the power.
Int ernal DC fan failure
Stop
・
A foreign object stuck in the DC fan stopped the
rotation of the fan.
・
DC fan is broken.
Turn off the power, and remove the foreign object from the
DC fan, if any.
If t he problem persist s, contact us.
Содержание ION WIPER DTY-WB01
Страница 1: ...X904484 ION WIPER Separate Type DTY WB01 DTY WBM01 S DTY WBM01 L Operating Instructions Ver 1 0 ...
Страница 23: ... 47 Box type A4 size DTY WBM01 S Aperture Aperture Depth ...
Страница 24: ... 48 Box type A3 size DTY WBM01 L Aperture Aperture Depth ...
Страница 25: ... 49 Memo ...
Страница 27: ...2018 年 12 月 Ver 1 0 KG KOGA NEI CORP PRINTED IN JA PA ...