4-2-3. Connecting the dust collecting unit
Connect the dust collecting unit connector CON3/CON4 when collecting dust using the dust collecting unit (DTY-ZMW01-□-□).
Up to two dust collecting units can be connected to a single blow unit.
(When the dust collecting units equipped with the dust sensors are connected to both of CON3 and CON4, the display and
output are based on the higher value of the dust sensors.
[Terminal array]
Terminal No.
Symbol
Connecting cable color
1
24 VDC
Brown
2
A(+)
White
3
B(-)
Blue
4
0 V
Black
5
NA(FG)
-
4-2-4. Connecting the photoelectronic sensor
When the photoelectronic sensor (DTY-ZSP□L-WB) is used, connect it to the photoelectronic sensor connector CON2.
[Terminal array]
Terminal No.
Symbol
Connecting cable color
1
24 VDC
Brown
2
NA
-
3
0 V
Blue
4
SIG
Black
The photoelectronic sensor can be installed to the nozzle surface of the blow unit. Use the enclosed screws to mount the
sensor. (Either of 2 positions)
4-2-5. Connecting the electrostatic potential sensor
When the electrostatic potential sensor (DTY-EPS01-EA-□LWB) is used, connect it to the electrostatic potential sensor connector
CON1.
Remove the coat of the tip of the electrostatic potential sensor cable (6 mm removal is recommended), crimp a rod terminal and
connect to CON1.
Ground the round terminal of the cable. (Connect it to a L-shape bracket fixing screw.)
For the specification details/use method of the electrostatic potential sensor, refer to the operating instructions of [Electrostatic
potential sensor DTY-EPS01].
[Terminal array]
Terminal No.
Symbol
Connecting cable color
1
24VDC
Brown
2
A(+)
White
3
0V
Blue
4
B(-)
Black
Connector for dust collecting unit 1
CON3
Connector for dust collecting unit 2
CON4
Photoelectronic sensor:
DTY-ZSP
□
L-WB
Connector for the
electrostatic potential
sensor
CON2
Connector for the electrostatic potential sensor
CON1
Electrostatic potential sensor:
DTY-EPS01-EA-
□
LWB
Dust collecting unit: DTY-ZMW01-□-□
Connect to the electrostatic
potential sensor
Connect to the blow unit
←
Ground
(Connect the round terminal)
Round terminal
Power connector 5-pin
Communication
connector 4-pin
Photoelectronic sensor installation positions
(M3 screw)
Electrostatic potential
sensor cable
Содержание ION WIPER DTY-WB01
Страница 1: ...X904484 ION WIPER Separate Type DTY WB01 DTY WBM01 S DTY WBM01 L Operating Instructions Ver 1 0 ...
Страница 23: ... 47 Box type A4 size DTY WBM01 S Aperture Aperture Depth ...
Страница 24: ... 48 Box type A3 size DTY WBM01 L Aperture Aperture Depth ...
Страница 25: ... 49 Memo ...
Страница 27: ...2018 年 12 月 Ver 1 0 KG KOGA NEI CORP PRINTED IN JA PA ...