- 37 -
52. LED Indicators
These indicators (turned on/flash/turned off) indicate the status of the blow unit and the additional parts.
For the details, refer to the LED status table.
(LED status table)
*1) To enable maintenance, enable the piano dip switch SW1/2 on the front of the blow unit.
(Refer to "7. Maintenance and Precautions" for details)
(Initial value) Ionizer discharge time: 300 [time]/frequency of air blow valve ON/OFF: 10 million times
Note: While the ion wiper is in operation, ensure that air is supplied to the equipped ionizer.
If the pressure setting of the ionized air regulator is less than 0.05 MPa, the device and the environment would receive harmful
effect.
Note: The particle removal effect by the ion wiper varies depending on the shape and the amount of charge of the workpiece (charged
material), air pressure, blow time, and blow intermittent frequency.
When this device is used, configure the ionized air pressure, blow flow rate/time/frequency appropriate to the workpiece.
Note: Value of the dust sensor is just a guide. It does not guarantee removal of dust from the workpiece.
Power LED POWER (green)
Alarm LED ALM (red)
Maintenance LED MAINT (yellow)
Ion blow LED ION BLOW (blue)
Electrostatic potential sensor LED EPS (yellow)
Dust sensor LED DUST (Blue/green/red)
LED
Item
POWER
(green)
ALM
(red)
MAINT
(yellow)
ION BLOW
(blue)
EPS
(yellow)
DUST
(red/green/
blue)
○
○
○
○
○
○
◎
○
○
○
○
○
●
-
-
-
-
-
●
-
-
●
-
-
Maintenance
*1)
Ionizer discharge needle
●
-
◎
(2Hz)
-
-
-
Air blow valve
●
-
◎
(4Hz)
-
-
-
Ionizer discharge needle/
Air blow valves (both)
●
-
●
-
-
-
Alarm
Ionizer
●
●
-
-
-
-
Blow unit
●
◎
(4Hz)
-
-
-
-
Dust collecting unit:
●
◎
(2Hz)
-
-
-
-
Electrostatic potential
sensor
●
◎
(1Hz)
-
-
-
-
Electrostatic
potential sensor
Judgment output ON
●
-
-
-
●
-
Zero-point calibration
execution
●
-
-
-
◎
(2s,2Hz)
-
Outside the measurement
range
●
-
-
-
◎
(4Hz)
-
Dust sensor
Dust amount: little
●
-
-
-
-
●
(Blue)
Dust amount: medium
●
-
-
-
-
●
(Green)
Dust amount: high
●
-
-
-
-
●
(Red)
Dust sensor not equipped
●
-
-
-
-
○
●
: On
◎
: Flash
○
: Off
Power OFF
Power ON
Blowing the ionized air
While starting up from the power ON
Содержание ION WIPER DTY-WB01
Страница 1: ...X904484 ION WIPER Separate Type DTY WB01 DTY WBM01 S DTY WBM01 L Operating Instructions Ver 1 0 ...
Страница 23: ... 47 Box type A4 size DTY WBM01 S Aperture Aperture Depth ...
Страница 24: ... 48 Box type A3 size DTY WBM01 L Aperture Aperture Depth ...
Страница 25: ... 49 Memo ...
Страница 27: ...2018 年 12 月 Ver 1 0 KG KOGA NEI CORP PRINTED IN JA PA ...