- 41 -
6-3-4. Read Holding Register (function code: 3)/ Preset Single Register (function code: 6)
Read by the function code 3, and overwrite by the function code 6.
(Readable and overwritable 16-bit data is deployed. The value of the retention register is maintained after the main unit is
turned off.)
Data
address
Term
Description
Initial
value
Maximum
value
Minimum
value
Unit
0
EPS Work size
Workpiece size setting for the electrostatic potential sensor
300
400
20
mm
1
EPS Distance
Measurement distance setting for the electrostatic potential
sensor
50
100
6
mm
2
EPS CP Thers
Threshold setting for the electrostatic potential sensor
* "EPS CP Thers > EPS CP Hys" must be satisfied.
100
20000
0
V
3
EPS CP Hys
Hysteresis setting for the electrostatic potential sensor
* "EPS CP Thers > EPS CP Hys" must be satisfied.
10
1000
0
V
4
EPS Mode
Mode setting for the electrostatic potential sensor
0: standard mode, 1: high voltage mode
0
1
0
8
FAN1 SPEED
Fan rotation speed setting for Dust collecting unit 1
8250
8250
2500
rpm
9
FAN2 SPEED
Fan rotation speed setting for Dust collecting unit 2
8250
8250
2500
rpm
10
FAN1 Mode
Operation mode setting for Fan 1
0: normal, 1: continuous (not turned OFF after the operation)
0
1
0
11
FAN2 Mode
Operation mode setting for Fan 2
0: normal, 1: continuous (not turned OFF after the operation)
0
1
0
16
DUST Thres
Dust sensor DUST signal threshold
* "DUST Thres >DUST Hys" must be satisfied.
50
1000
0
-
17
DUST Hys
Dust sensor DUST signal hysteresis
* "DUST Thres >DUST Hys" must be satisfied.
10
100
0
-
18
DUST Led DH
Dust sensor LED threshold DH
Detected value >= DH: red LED turned on
DH > Detected value > DL: green LED turned on
Detected value <= DL: blue LED turned on
200
1000
0
-
19
DUST Led DL
Dust sensor LED threshold DL
Detected value >= DH: red LED turned on
DH > Detected value > DL: green LED turned on
Detected value <= DL: blue LED turned on
50
1000
0
-
21
End Count H
Operation completion count upper
0
30000
0
x10,000
times
22
End Count L
Operation completion count lower
0
9999
0
time(s)
23
ELK Clean H
Ionizer discharge time (hour)
Automatic count at discharge
0
30000
0
h
24
EKL Clean S
Ionizer discharge time (second)
Automatic count at discharge
* Ensure to clear to 0 after a maintenance task completes.
0
3599
0
s
25
ELK Clean
Thres
Discharge needle maintenance time setting
(for MAINT output)
300
30000
0
h
26
Blow Valve
CntH
Blow valve actuating cycle upper
0
10000
x10,000
times
27
Blow Valve
CntL
Blow valve actuating cycle lower
* Ensure to clear to 0 after a maintenance task completes.
0
9999
0
time(s)
28
Blow Valve Cnt
Thres
Blow valve replacement (for MAINT output)
1000
10000
0
x10,000
times
32
UA1 ON Delay
User area 1 ON delay time: T1
100
3000
0
ms
33
UA1 ON FAN
User area 1 pre-blow blow time: T2
200
3000
0
ms
34
UA1 ON ELK
User area 1 pre-blow discharge time: T3
100
3000
0
ms
35
UA1 Blow Time
User area 1 blow time: T4
1000
60000
500
ms
36
UA1 OFF ELK
User area 1 post-blow discharge time: T5
0
3000
0
ms
37
UA1 OFF FAN
User area 1 post-blow blow time: T6
200
3000
0
ms
38
UA1 OFF
Delay
User area 1 OFF delay time: T8
100
3000
0
ms
39
UA1 Blow Freq
User area 1 blow frequency
0: continuous, 10 - 100: pulse blow
0
100
0
x0.1 Hz
40
UA1 Mode
User area 1 operation mode
0: blow time specifying mode, 1: continuous mode
0
1
0
48
UA2 ON Delay
User area 2 ON delay time: T1
100
3000
0
ms
49
UA2 ON FAN
User area 2 pre-blow blow time: T2
200
3000
0
ms
50
UA2 ON ELK
User area 2 pre-blow discharge time: T3
100
3000
0
ms
51
UA2 Blow Time
User area 2 blow time: T4
1000
60000
500
ms
52
UA2 OFF ELK
User area 2 post-blow discharge time: T5
0
3000
0
ms
53
UA2 OFF FAN
User area 2 post-blow blow time: T6
200
3000
0
ms
54
UA2 OFF
Delay
User area 2 OFF delay time: T8
100
3000
0
ms
55
UA2 Blow Freq
User area 2 blow frequency
0: continuous, 10 - 100: pulse blow
0
100
0
x0.1 Hz
56
UA2 Mode
User area 2 operation mode
0: blow time specifying mode, 1: continuous mode
0
1
0
*) Data addresses 32 - 40 and data addresses 48 - 56 are enabled when the blow intermittent frequency switch [FREQ]No.8 and the
glow intermittent frequency switch [FREQ]No.9 are set, respectively. For their behavior, refer to the [time chart] on page 11.
Содержание ION WIPER DTY-WB01
Страница 1: ...X904484 ION WIPER Separate Type DTY WB01 DTY WBM01 S DTY WBM01 L Operating Instructions Ver 1 0 ...
Страница 23: ... 47 Box type A4 size DTY WBM01 S Aperture Aperture Depth ...
Страница 24: ... 48 Box type A3 size DTY WBM01 L Aperture Aperture Depth ...
Страница 25: ... 49 Memo ...
Страница 27: ...2018 年 12 月 Ver 1 0 KG KOGA NEI CORP PRINTED IN JA PA ...