- 34 -
5. Operation
51. Operation procedures
(1) Ensure the power connection, grounding, air piping, wiring, and exhaust ventilation (dust collecting unit/duct piping).
(Working pressure range: 0.2 - 0.7 MPa)
(2) Open the valve source of the air device (installed by the customer) and adjust the throttle valve for the ionized air regulator/air
blow.
Adjust the ionizer supply air pressure to be within a range of 0.05 - 0.5 MPa.
When turning on this device, always input the
air.
(Ionized air regulator)
Rotate the regulator handle with the handle securely pulled out. Rotate clockwise to increase the pressure, and rotate counter-
clockwise to decrease the pressure.
After the adjustment completes, push the handle to lock it.
Check the pressure with the pressure gauge at the front of the blow unit. (Setting range: 0.05 - 0.5 MPa)
(Throttle valve for air blow)
Rotate the throttle valve needle from the fully open position to the counter-clockwise direction to increase the blow flow rate.
When the desired flow rate is achieved, always fasten the locknut to secure the setting.
When the needle is rotated too much (the flow rate is too high), rotate the handle clockwise to decrease the flow rate.
(3) Set the blow time and blow intermittent frequency using the blow time switch TIME/blow intermittent frequency switch FREQ.
For the blow time, either use the timer setting (0.5 - 10.0 seconds) or select the blow time switch No. from the continuous setting.
When the timer setting is used (blow time setting switch No.0 - A), the product blows the air for the configured time.
When the continuous setting is used (blow time setting switch No. B - F), the product blows the air when the photoelectronic sensor
detects the workpiece.
For the continuous setting, the sensor OFF delay time can also be selected. When removing particles manually, for example, the
products keeps blowing the air during the OFF delay time if the target workpiece is out of the range of the photoelectronic sensor. If
the workpiece is detected again during the OFF delay time, the OFF delay time is reset.
When the blow intermittent frequency setting is used, the product provides intermittent blow at the frequency specified by the blow
intermittent frequency switch No.
Set the switch No. to "0" to disable intermittent blow.
The blow intermittent frequency switch No.8/No.9 are the user area that allows the customer to set desired behaviors.
There are two areas. The blow time/intermittent frequency/operation interval time can be configured according to the user
environment.
For details, refer to Section 6-3-4. (Setting via communication is required.)
Note: The intermittent operation is available for air blow only. Intermittent blow is not available for the ionized air.
Ionized air regulator
Throttle valve for air blow
Needle
Locknut
Handle
< 0.5 MPa
> 0.05 MPa
Blow time switch
TIME
Blow intermittent frequency switch
FREQ
(Blow time switch)
(Blow intermittent frequency switch)
Blow time switch Blow time
Remark
No.
[second]
0
0.5
-
1
1.0
-
2
2.0
-
3
3.0
-
4
4.0
-
5
5.0
-
6
6.0
-
7
7.0
-
8
8.0
-
9
9.0
-
A
10.0
-
B
Continue Sensor OFF_delay tim e
0.1 s econd
C
Continue Sensor OFF_delay tim e
0.5 s econd
D
Continue Sensor OFF_delay tim e
1.0 s econd
E
Continue
Se nso r OFF_d ela y time
2.0 seco nds
F
Continue
Se nso r OFF_d ela y time
3.0 seco nds
Blow intermittent
frequency s witch No.
Blow frequency
[Hz]
Remark
0
0
No intermittent
operation
1
1
-
2
2
-
3
3
-
4
4
-
5
6
-
6
8
-
7
10
-
8
User area 1
-
9
User area 2
-
Increase
pressure
Decrease
pressure
Unlock
Lock
Содержание ION WIPER DTY-WB01
Страница 1: ...X904484 ION WIPER Separate Type DTY WB01 DTY WBM01 S DTY WBM01 L Operating Instructions Ver 1 0 ...
Страница 23: ... 47 Box type A4 size DTY WBM01 S Aperture Aperture Depth ...
Страница 24: ... 48 Box type A3 size DTY WBM01 L Aperture Aperture Depth ...
Страница 25: ... 49 Memo ...
Страница 27: ...2018 年 12 月 Ver 1 0 KG KOGA NEI CORP PRINTED IN JA PA ...