3. Device Configuration and Features
The blow unit consists of various functional parts, including the ionizer (DTY-ELK01) and valves, as well as the electric/air control circuits
that operate these functional parts.
For collecting dusts, an additional part -- dust collecting unit (DTY-ZMW01) -- is available.
31. Terms and Functions of Each Part
[Blow unit: DTY-WB01-□-□]
[Dust collecting unit: DTY-ZMW01-□-□]
Unit
Term
Feature
Reference Section
Blow unit
Power connector
Power 24 V/0 V/FG is connected.
4-2-1. Power and ground
connection
I/O connectors
These connectors are used to connect PLC and other components to control
the blow unit.
4-2-2. Connecting to external
devices
Connectors for the dust
collecting units 1 & 2
These connectors are used to connect to the dust collecting units.
4-2-3. Connecting the dust
collecting unit
Connector for the
photoelectronic sensor
This connector is used to connect the photoelectronic sensor.
4-2-4. Connecting the
photoelectronic sensor
Connector for the
electrostatic potential
sensor
This connector is used to connect the electrostatic potential sensor.
4-2-5. Connecting the
electrostatic potential sensor
Communication
This port is used to connect to an external device such as a PC, and to
retrieve various settings and information.
4-2-6. Connecting
communication devices
6. Communication
Air IN port
This is a piping port for the air blow and ionized air.
4-3. Air Piping
Nozzle (ionized air outlet)
This is the nozzle from which the ionized air (for static charge removal) is
blown out.
4-3. Air Piping
Nozzle (blow air outlet)
This is the nozzle from which the blow air (for static charge removal) is blown
out.
4-3. Air Piping
Throttle valve for air blow
This valve adjusts the flow rate of the blow air (for static charge removal).
5-1. Operation Procedures (2)
Ionized air regulator
This component adjusts the impressed pressure of the ionizer.
5-1. Operation Procedures (2)
Pressure gauge (for ionized
air)
This component displays the pressure applied to the built-in ionizer.
(Configured on the ionized air regulator)
5-1. Operation Procedures (2)
Setting switches
These switches are used to set the blow time/blow intermittent frequency.
5-1. Operation Procedures (3)
Power switch
This switch is used to turn on/off the blow unit and the additional parts.
5-1. Operation Procedures (4)
LED indicators
These indicators indicate the status of the blow unit and the additional parts.
5-2. LED Indicators
Dust
collecting
unit
Dust collecting cable
This cable is connected to the blow unit.
4-2-3. Connecting the dust
collecting unit
Fan filter (IN)
This is the filter on the suction side.
(This filter is designed to prevent foreign objects such as screws from entering
inside the product)
4-4. Exhaust Ventilation
Fan filter (OUT)
This is the filter on the exhaust side.
4-4. Exhaust Ventilation
Pressure gauge (for ionized air)
Setting pressure range: 0.05 - 0.5 MPa
Setting switches
Power switch
Nozzle (ionized air outlet)
Nozzle (blow air outlet)
Throttle valve for air blow
Ionized air regulator
*) set to a value within a
range of 0.05 - 0.5 MPa using
the pressure gauge (for
ionized air)
Connector for the
electrostatic
potential sensor
Air IN port (
φ
8 quick joint)
Impressed pressure range:
0.2 - 0.7 MPa
Connector for the
photoelectronic
sensor
Connector for the dust
collecting unit 2
Connector for the dust
collecting unit 1
Dust collecting cable
Fan filter (OUT)
Fan filter (IN)
Power connector
I/O connectors
LED indicators
Communication
Содержание ION WIPER DTY-WB01
Страница 1: ...X904484 ION WIPER Separate Type DTY WB01 DTY WBM01 S DTY WBM01 L Operating Instructions Ver 1 0 ...
Страница 23: ... 47 Box type A4 size DTY WBM01 S Aperture Aperture Depth ...
Страница 24: ... 48 Box type A3 size DTY WBM01 L Aperture Aperture Depth ...
Страница 25: ... 49 Memo ...
Страница 27: ...2018 年 12 月 Ver 1 0 KG KOGA NEI CORP PRINTED IN JA PA ...