EtherNet/IP Connection Procedure
12
7.2. KOGANEI Manifold Solenoid Valve Setup
Set up the KOGANEI Manifold Solenoid Valve.
7.2.1. Hardware Settings
Connect the cables to the Manifold Solenoid Valve.
Precautions for Correct Use
Make sure that the power supplies are OFF when you set up.
If either of them is ON, the settings described in the following steps and subsequent
procedures may not be applicable.
1
Make sure that Switching hub
power supply and Power supply
for Manifold Solenoid Valve are
OFF.
2
Check the position of the
connectors by referring to the
figure on the right.
Power supply, communication, and FG sections
3
Connect Switching hub and
Communication connector (L/A
IN) on Manifold Solenoid Valve
with a LAN cable.
Connect Switching hub and
Personal computer with a LAN
cable.
4
Connect Power supply for
Manifold Solenoid Valve to
Power supply connector (PWR)
on Manifold Solenoid Valve.
*For details on power supply
specifications and connections
for Manifold Solenoid Valve,
refer to the
EtherNet/IP
Compliant Serial Transmission
Compatible Manifold User’s
Manual
(BK-HV045).
LAN cable
LAN cable
Personal computer
Switching hub
Manifold Solenoid Valve
Power supply for Manifold Solenoid Valve
Manifold Solenoid Valve