7
.
EtherNet/IP Connection Procedure
14
7.2.2. Parameter Settings
Set the IP address of the Manifold Solenoid Valve.
The IP Address is set using the BOOTP/DHCP Tool.
Install the Tool on your personal computer beforehand.
1
Make sure that Manifold
Solenoid Valve and Switching
hub are powered OFF.
2
Set the IP address and subnet
mask of Personal computer as
shown below.
・
IP address:
192.168.250.10
・
Subnet mask:
255.255.255.0
*It is necessary to set the IP
address of Personal computer
to "192.168.250.* " so that the
IP address of Manifold
Solenoid Valve can be set to
"192.168.250.2".
The IP address set in this guide
is "192.168.250.10".
Screenshot of Windows network settings
3
Check the positions of LEDs and
Host address setting switch by
referring to the figure on the
right.
4
Check that Host address setting
switch is set to 000 (Set the IP
address by software).
*If not, set the switch to
000
.