7.5.2. Checking Sent Data
Check that correct data is sent.
In this procedure, the output of the Manifold Solenoid Valve is performed, which
may have a risk of unexpected operation of the devices connected to the
Manifold Solenoid Valve.
Ensure safety before you proceed with this operation check described here.
If you cannot ensure safety, do not proceed.
When you perform this operation check, make sure to complete all the steps and
make the output of the Manifold Solenoid Valve safe.
If you change the variable values on a Watch Tab Page when Sysmac Studio is
online with the CPU Unit, the devices connected to Output Units may operate
regardless of the operating mode of the CPU Unit.
Always ensure safety before you change the variable values on a Watch Tab
Page when Sysmac Studio is online with the CPU Unit.
1
Select
Watch Tab Page
from
the View Menu in Sysmac
Studio.
2
Select the
Watch1
Tab.
3
Click
Input Name
and enter the
following variable name.
EIP002_OUT[0]
4
Check that the online value of
EIP002_OUT[0]
is False.