EtherNet/IP Connection Procedure
36
■Editing Settings for the Connection
Connection setting
Set value
Connection I/O Type
Exclusive Owner
Originator Device
Output Tag Set
EIP002_OUT-[4 Byte]
Connection Type
Point to Point connection
Target Device
Input Tag Set
Output_100-[4 Byte]
4
Check that the settings are
correct. Click
Regist
.
5
The Edit Connection Dialog Box
is displayed again.
Do not enter any values but
simply click
Close
.
6
The Edit Device Parameters
Dialog Box is displayed again.
Check that the connection set
for 192.168.250.2 is registered.
Click
OK
.
7
The registered IP address is
displayed under the device icon
of Manifold Solenoid Valve
(Node 2) in the Network
Configuration Pane.
*It indicates that the connection
settings are completed.