7
.
EtherNet/IP Connection Procedure
16
9
Turn ON Manifold Solenoid
Valve. Check that the MS
indicator (LED) on Manifold
Solenoid Valve flashes green
(IP address setting in progress).
*A DHCP request will start to be
sent by Manifold Solenoid
Valve once turning it ON.
*If the MS indicator (LED) on
Manifold Solenoid Valve does
not flash green, it means that
Manifold Solenoid Valve does
not send a DHCP request.
In that case, restore the
settings of Manifold Solenoid
Valve to factory defaults, and
repeat from step 1. For
information on how to restore
the settings of Manifold
Solenoid Valve, refer to
Section 8. Initialization Method
.
10
With BOOTP/DHCP Tool, the
DHCP request sent by Manifold
Solenoid Valve is displayed in
the
Discovery History
Field as
shown in the figure on the right.
Double-click the DHCP request.
*If Manifold Solenoid Valve
stops sending continuous
DHCP requests due to a
timeout, turn OFF Manifold
Solenoid Valve, then turn it
back ON.
11
The New Entry Dialog Box is
displayed.
Enter the IP address of Manifold
Solenoid Valve in the
IP
Field as
shown on the right. Click
OK
.
*The IP address is set to
"192.168.250.2" in this guide.
LEDs
Power supply for Manifold Solenoid Valve
Switching hub
Switching hub power supply
Содержание F Series
Страница 49: ...46 ...