42
8. Control system
8.2 Serrating (Re-serrating)
To re-serrate a knife, the parameter “Re-serrate
Knife” (8-2/1) in the sub-menu “F5 Grinding
Data” (see Chapter 8.4) must be set to “True”
(here, to “False”).
ATTENTION
Before program start, go to the sub-menu “F1
Serrate” (8-4) via “F8 Settings” (3-9/14).
Activate “Measure” with “F3 Enable / Disable”
(8-4/6) and “Serrate” with “F7 Enable / Dis-
able” (8-4/9).
After activation, the program is started with “F1
Automatic START” (3-9/7).
The laser remains in standby position in front of
the knife to wait for the manual position setting
of the serration tooth.
Go again to the sub-menu “F1 Serrate” (8-4) via
“F8 Settings” (3-9/14).
Figure 8-2
Re-serrating
Figure 8-3
Laser in standby position
1
1