29
All work on the machine may only be performed by authorized
personnel.
The locally applicable safety and accident prevention regulations must be
observed.
Connect compressed air only when the doors are closed.
Never cut off the compressed air while the knives are clamped. This can
result in serious injuries.
CAUTION
Fill the water trough to 5 cm below the rim with water.
Open the safety doors.
Set the coolant hose (6-1/1) as illustrated in the
figure. The distance between the rear grinding
wheel (6-1/2) and the front grinding wheel (6-1/3)
should be approx. 5 cm. The coolant hose must
not touch the grinding wheels.
ATTENTION
Observe the minimum distance between
coolant hose and grinding wheels, as the
grinding wheels move forward when
grinding.
Connect the power plug (CEE plug) to the power socket provided on site (3x 400 V, 32 A).
Plug in the compressed air hose at the compressed
air port (6-2/1).
Close the safety doors.
6. Commissioning
Figure 6-2
Compressed air connection
1
Figure 6-1
Setting the coolant hose
1
2
1
3