EN UG-020 Link 6 user guide r1.0
64
Equally important in knowing the timeline of a safety function is knowing where to find the
current safety function status. For the status of SF05 Monitored stop0 function, there is one
place to look in Kortex Web App:
Diagnostics
>
Status
>
Safety Functions
.
Table 44: SF06 trigger and action timeline
Monitor frequency of trigger
0.01 s
Trigger
• Any part of the flange enters at least one protection zone.
• Any part of the tool enters at least one protection zone.
• Any checkpoint enters at least one protection zone.
Trigger results
• Stop category 2 is deployed.
• The arm is in the state Fault power on.
Reset conditions
All conditions must be met.
• Tool sphere is outside all configured protection zones.
• All checkpoints are outside all configured protection zones.
Reset
Tap
CLEAR FAULT
.
Reset result
• The operating mode is Monitored Stop.
• The arm does not move.
Failsafe
SF06 can experience processing errors. In this case, stop category 0
is deployed.
Brake
Release
Idle
Initialization
Maintenance
Fault
power on
Operational
Recovery
SF06
active
SF06
inactive
Arm:
Operating modes:
SF06
partially
active
Figure 47: Timeline for SF06 before and after being triggered
Related topics
State timeline for the safety output Normal Speed Mode