EN UG-020 Link 6 user guide r1.0
234
1.
Take note of the exact error along with the conditions that seem to have triggered it.
Tip:
When a fault triggers, a message launches in Kortex Web App that provides
information.
• Name of the fault
• Error code
• Explanation of what can trigger the fault
• What can be done to fix the problem
2.
Reboot the controller.
3.
Re-install the
SWU
if the error persists.
4.
If the problem persists, contact support at [email protected].
Related topics
on page 226
Remedy for MCU firmware corruption
Many different errors of the status of the
can be caused by corrupted
on the
MCU
.
About this task
Take the same remedial steps for each of the actuator status.
• Startup self-tests timed out
•
MCU
core general purpose registers self-test failure
•
MCU
core arithmetic functions self-test failure
•
MCU
core multiplier functions self-test failure
•
MCU
core control flow instructions self-test failure
•
MCU
core load store unit self-test failure
•
MCU
core stack pointer self-test failure
•
MCU
core pipeline functions self-test failure
•
MCU
core FPU registers bank self-test failure
•
MCU
core FPU single precision functions self-test failure
Procedure
1.
Take note of the exact error along with the conditions that seem to have triggered it.
2.
3.
Re-install the
SWU
if the error persists.
4.
If the problem persists, contact support at [email protected].
Emergency stop button signals disagreement
What does
Emergency stop button signals disagreement
monitor?
Emergency stop button signals disagreement
monitors whether the signals coming from the
emergency stop button are in alignment with the state of the robot.
Cause
The emergency stop button may not be fully engaged or fully released.