• Make sure the controller has enough room to dissipate heat properly.
Related topics
Considerations before installing the controller
on page 115
Maximum current reached
What does
Maximum current reached
monitor?
Maximum current reached
monitors whether the electrical current pulled by the
stays
below a certain amount.
Cause of the trigger
The instantaneous power pulled by the robot for its motion in addition to the power required by
the components of the controller may exceed the limits of the hardware.
Procedure
• Avoid having computationally expensive algorithms running on the controller when the robot
has to apply high torques if possible.
• Reduce the force or velocity output by the robot during its trajectory.
Network error
What does
Network error
monitor?
Network error
monitors whether the controller can find all the expected devices on its network.
Cause of the trigger
Communication packets may be lost between the internal devices of the robot.
Procedure
1.
Take note of the exact error along with the conditions that seem to have triggered it.
2.
Reboot the controller.
3.
Re-install the
SWU
package if the problem persists.
4.
If the problem persists, contact support at [email protected].
Procedure
1.
Reboot the controller.
2.
Re-install the
SWU
package if the problem persists.
3.
Contact support at [email protected].
Self-collision detected
What does
Self-collision detected
monitor?
Self-collision detected
monitors whether non-consecutive robot links are at risk of entering in
contact with each other.