EN UG-020 Link 6 user guide r1.0
270
Why is the controller hot?
Condition
SCU
or the
MCU
are
overheating.
Cause
The temperature of the SCU core or MCU board is too high.
Remedy
Procedure
• Check the controller fans are spinning freely.
• Check that neither the controller fans nor the fan filter are clogged.
Issues related to safety elements
Examples of safety-related issues that you may have deal with the safety configurations and
safety I/O connections.
Why can I not edit any safety configurations?
Condition
None of the parameters on any of the
Safety
pages are modifiable.
Note:
This condition only happens when the user is an
operator
and is not an
admin user
.
Cause
The user is an operator. Only admin users can modify safety configurations.
Remedy
Procedure
• Tap
>
ELEVATE PERMISSIONS
and enter the admin password.
• Contact an admin user to discuss which safeties may need to be modified.
Why is the external safety device not working?
Condition
The external device attached to the robot is not working. The robot is in a
stop category
0, where
there is no electrical power in the robot.
Cause
The device is not configured correctly on the safety I/O channel.