EN UG-020 Link 6 user guide r1.0
227
Status of the safety actuators
No kinematics support
What does
No kinematics support
monitor?
No kinematics support
monitors whether the
can find the kinematic information to
control the
properly.
Cause of the trigger
The files that contain the information in the file system of the controller may be corrupted.
Procedure
1.
Take note of the exact error along with the conditions that seem to have triggered it.
2.
Reboot the controller.
3.
Re-install the
SWU
package if the problem persists.
4.
If the problem persists, contact support at [email protected].
Maximum ambient temperature reached
What does
Maximum ambient temperature reached
monitor?
Maximum ambient temperature reached
monitors the ambient temperature.
Cause of the trigger
• The room where the
is installed may be too warm.
• There is not enough space behind the controller for its fan to disperse its internal heat
properly; the temperature close to the controller is warmer than the actual temperature of the
room.
Remedy
Make sure the controller has enough room to dissipate heat properly and that it operates under
the recommended conditions.
Related topics
Considerations before installing the controller
on page 115
Maximum core temperature reached
What does
Maximum core temperature reached
monitor?
Maximum core temperature reached
monitors the temperature within the core of the
. It
must not exceed 75 °C.
Cause of the trigger
The fan within the controller is not able to dissipate heat efficiently enough.
Procedure
• Make sure the air filters on the controller are clean.
• Make sure the fan is spinning freely.
+1 514-277-3777
kinovarobotics.com
© 2022 Kinova inc. All rights reserved.