261
Preventive maintenance
Always perform preventive maintenance within the time scheduled maintenance time frame to
avoid downtime of the robot.
Different parts of Link 6 require maintenance checks on a daily, weekly, quarterly, or yearly
schedule. Some preventive maintenance does not adhere to a specific schedule.
Daily maintenance
Always perform daily tasks daily to avoid downtime of the robot.
Table 99: Daily checks for preventive maintenance
Validation task
Corrective action
Check the emergency stop functions as expected.
Contact support at [email protected].
Check all states of the 3-position enabling device
function as expected if it is expected to be used.
Contact support at [email protected].
Check all terminal connections are secured.
Redo connections.
Check the cables are in good condition with no rips,
tears, or frays.
Contact support at [email protected].
Check the robot joint caps are installed properly on
the robot with no visible gaps and secure.
Contact support at [email protected].
Check the tools and accessories are attached
correctly and are not loose.
Secure the tools and accessories.
Check the joints are not loose.
Contact support at [email protected].
Check the bolts on the base are tightened according
to the specifications and the base does not move
when the robot moves.
Secure the base of the arm.
Check the casing of the controller is closed, with no
openings along the edges or elsewhere.
Contact support at [email protected].
Check the I/O panel on the controller is closed.
Close the panels on the controller.
Check the end caps are on all electrical connectors
that are not in use.
Place end caps on all exposed electrical
connectors.
Check the environment is the same as usual, with
no additional objects in the area.
Remove objects that normally are not in the
environment.
Weekly maintenance
Always perform weekly tasks weekly to avoid downtime of the robot.
Table 100: Weekly checks for preventive maintenance
Validation task
Corrective action
Check the air filter in the controller is clean.
Replace the air filter.