EN UG-020 Link 6 user guide r1.0
157
Procedure
Configuring the gravity vector of the arm
When the robot is unboxed, the robot is oriented sideways. The controller expects the robot to be
oriented up with gravity pointing down. After the robot is installed, the values for
Gravity Vector
must be verified, especially when the robot is installed on a wall, ceiling, or other location that is
not on a table or floor, because it is not oriented up.
1.
Tap
Gravity Vector
to access configurable parameters of the gravity vector of the arm.
The
Gravity Vector
pane launches.
2.
Enter values for
x
,
y
, and
z
in m/s
2
, expressed in the Base reference system.
3.
Tap
SEND
.
A confirmation dialog launches when errors are suspected.
4.
Tap
PROCEED
to send the gravity vector values to the controller or tap
CANCEL
to cancel the
operation.
5.
Tap
CLEAR
to erase the values entered that have not been sent.
+1 514-277-3777
kinovarobotics.com
© 2022 Kinova inc. All rights reserved.
Содержание Link 6
Страница 1: ...Link 6 user guide Optional gripper shown ...
Страница 8: ......