EN UG-020 Link 6 user guide r1.0
34
Industrial I/O power supply
Negative connections, labeled as 0V, are only for power and signaling.
protective earth (PE)
provides a low impedance path to ensure proper functioning in case of faults.
Be careful to connect power to the supplies correctly. When connected incorrectly, you can
have undesirable side effects, such as reverse polarity, improper voltage levels, and improper
frequencies. Link 6 is designed such that the 24V_IN and 0V_IN terminals are protected against
reverse polarity.
Important:
Use only
DC
signals.
Important:
Do not exceed 28 V under any conditions.
During the power up sequence, all outputs are low and all inputs are not read.
During the power down sequence, all outputs shut down to the low state. The output from the
emergency stop (E-stop)
enters a low state; it generates and
E-stop
event on all external devices
connected to this terminal. All inputs are not read.
Table 16: Internal power
Internal 24 V power supply
Min
Typical
Max
Unit
Voltage
23.5
24
24.5
V
Current (total)
2
A
Table 17: External power
External 24 V input
requirements
Min
Typical
Max
Unit
Note
Voltage
20
24
28
V
Designed for IEC 61131-2
Current (total)
5
A
Fused internally at 10 A. The
external power supply should
be fused to a lesser value. It is
recommended to fuse it at 5 A
with an opening time that is less
than 5 seconds.
The terminal connections belong to the POWER terminal group.
Table 18: Power terminal connections
Label
Purpose
24V_IN
24 V input to supply the general purpose
I/O
s.
0V_IN
0 V input to supply the general purpose
I/O
s.
24V_OUT
24 V output of the internal
I/O
power supply.
Use only to jump with the terminal 24V_IN.
If an external power supply is used to connect on the 24V_IN
terminal, leave the terminal unconnected.